tubing tolerances
ID inside diameter & OD outside diameter


 

nominal inches,
diameter

plus or minus (±) tolerance, inches

outside diameter
(reference vertical arrows)

inside diameter
(reference horizontal arrows)

ID inside diameter

OD outside diameter

steel
mandrel

built-up
mandrel

.125" -.749"

.003"

-

.005"

.750" - 1.999"

.004"

-

.005"

2.000" - 4.000"

.008"

-

.008"

 

*turned

*as wound

4.001" - 12.000"

.010"

-

.025"

plus only

12.001" - 18.000"

.030"

.060"

.030"

plus only

18.001" - 24.000"

.040"

.075"

.035"

plus only

24.001" - 48.000"

.060"

.090"

.040"

plus only

*Note: tubing over 8.000" OD supplied as wound (turned OD quoted on request)

 